Description
Overview
- Suitable for commercial offices and schools
- Perfect for higher humidity environments
- Airflow Rate of 1000 m3/hr
- 250 mm duct diameter
- Side and rear spigot options to external pipes
- Up to 90% heat Recovery rate
The Mitsubishi LGH-100 RVS-E is a popular commercial heat recovery unit and is suitable for any type of commercial application including shower and changing rooms due to the latest PVC heat exchanger
BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems.
Key features- Mitsubishi Lossnay LGH-100 RVS-E
- Airflow Rate of 1000 m3/hr
- 250 mm duct diameter
- Side and rear spigot options to external pipes
- Up to 90% heat Recovery rate
- Latest PVC core suitable for wet areas
- compliance with Part L
- Optional Mitsubishi Electric energy saving CO2 sensors
- 100% Summer By-Pass
- Lightweight structure ideal for easy ceiling installation
- Optional digital Controller
- Optional F7 filtration
- 0-10V input option.
Controllability
- Volt Free contact
- PCB Dipswitch function
- Optional Controller
- Optional 12v signal
- Optional External sensors
- Optional 0-10v DC Input
- Optional Wi-Fi Interface
- Optional M-Net connectivity
- Control compatibility with Mr Slim and City Multi air conditioning systems for a complete and highly effective system operation
Wall LCD controller (optional)
The optional wall controller PZ-62DR-EB will allow you to
- Adjust Fan Speed in 5% increments
- Automatic control
- Filter warning
- Weekley Timer
- Nighttime Purge
- Summer By-Pass
- Temperature
- Optional Co2 display
- Maintenance and Run Time
- Connect to other Mitsubishi products
- Operate Multiple Units (max 15)
Co2 Sensors
With the option of an additional CO2 sensor. When connected with the optional Wi-Fi Control Interface, CO2 levels can be viewed in real-time making it ideal for schools, medical facilities and offices.
It is well known that poor air quality impacts health, wellbeing and concentration levels. In conjunction with the CO2 sensor, the Lossnay LGH-RVX3-E system intuitively adjusts airflow to ensure optimum air quality, no matter how many people are in the room.
Two types of CO2 sensors are available: wall-mounted and duct-mounted types. Power is supplied to the CO2 sensor from the Lossnay board.
Construction
The Mitsubishi LGH units’ range are manufactured of airtight and noise absorbing EPP with a metal outer cover
Motors
High quality commercial motors with Dual-Barrier coating on the fan prevents dust and grease accumulation, ensuring long-term efficient operation
Flexible supply and exhaust fan commissioning in 5% increments, offering low running costs and easier
The default fan speed value (Fan speed 1: 25%, Fan speed 2: 50%, Fan speed 3: 75%, and Fan speed 4: 100%) of both supply air and exhaust air can be adjusted flexibly. Within the range between 25% and 100%, airflow can be adjusted by 5% increments to satisfactorily meet the designed airflow rate.
Dual Barrier Coating
Dual Barrier Coating prevents dust and oil build-up on the interior of the Lossnay unit, helping to keep it clean for optimal performance. A water-repellent effect is achieved by creating a coating film that has nano-sized concave-convex structures formed by silica nanoparticles made of water-repellent fluor resin and micron-sized concave-convex structures formed by combining micronized special-shaped particles (silicate) with the silica nanoparticles. At the same time, the uneven structure forms an air layer that suppresses the adhesion of dust and sand that contain a lot of humidity, reducing the amount of dirt that adheres to the substrate.
Filtration
- 2 x G3 filters are fitted to the unit that are easy to replace
- Optional F7 to air supply
Summer By-Pass
The units have a 100% summer by-Pass
Heat Exchanger
The PVC heat exchange can recover up to 90% of normally wasted heat and can be used in areas of high humidity like showers and changing rooms
Frost Protection
The unit has a frost protection programme
Orientation
The unit is available in only one orientation
The external pipes can be repositioned from the rear to side if required
Mounting
The units are supplied with ceiling mounting brackets and optional wall mounting brackets are available
Warranty
Mitsubishi offer a 3-year warranty with this unit
Accessories
- Remote controller – PZ-62DR-EB
- Standard Filters – PZ-100RF3-E
- F7 Filter – PZ-100RFP3-E
- Wall Mounted Co2 Sensor – PZ-70CSW-E
- Duct Mounted Co2 Sensor – PZ-70CSD-E
- Vertical Mounting Bracket – PZ-1VS-E
Further Information
Further information is available on the Manufactures website (Click Here)
Technical
Model |
LGH-100RVS-E |
Heat Recovery efficiency % |
90 |
Airflow rate @ 100-Pa m3/h |
1000 |
SFP (lowest) |
0.5 |
Dimensions W x H x D (mm) |
1185-997-465 |
Weight Kg |
73 |
Filtration |
2XG3 |
Pre/ Post Heater |
x |
Summer Bypass |
Yes |
Frost protection |
Yes |
Sound level @3m db.(a) |
18-37 |
Mounting |
Ceiling / Floor |
Ductwork Connection Location |
Side |
Ductwork Diameter |
250 |
Condensate drain |
Yes |
Warranty |
3 Years |
Country of manufacture |
Japan |
Heat exchanger |
Counterflow |
Digital Controller |
Optional |
Boost Switch control |
Yes |
Interactive App Control |
No |
Internal Humidity control |
No |
Internal Co2 Sensor |
No |
Electronic Orientation change |
No |
Available room sensors |
Yes |
BMS |
Yes |
KNX |
No |
Fireplace mode |
No |
Alarm system integration |
Optional |
SAP Appendix Q |
No |
Passive House Approved |
No |