DucoBox Connect MEV
The DucoBox silent Connect is a high-quality demand controlled MEV unit that extracts continually from the kitchen and bathrooms to one central unit to provides a quiet and efficient ventilation system
The difference between the DucoBox Silent Uk and DucoBox silent connect is that there is additional possibility to connect several additional features of Wall mounted Wired or RF Remote controls, Room sensors, Connectivity board allowing control via APP and the possible use of the optional commissioning App kit
The unit does not come with any sensors and all options are at extra cost
Demand controlled with optional internal humidity or Co2 box sensor that will automatically increase the speed to lower high humidity levels
Manufactured in Belgium and developed with double wall construction to provide the quietist MEV available in Europe
With a high performance of 400 m3/hr. this unit is ideally suited for high quality new builds or high-end renovations with up to 7 extract points
The DucoBox silent has 7 x125mm connections and 1 x 125mm outlet
With the optional Q-V adaptors this unit is also suitable with the use of up to 7 x 90mm crushproof radial ductwork connections with antibacterial lining that will lower the installation time and comply to the latest building control regulations
BPC are MEV specialists and the original developers of MEV kits in the Uk and Ireland with lifetime technical support on our top-quality systems
Key Features
- Suitable for up to 7 bathrooms
- Quietest MEV unit in Europe
- Powerful airflow rate of up to 400 m³/hour @ 150 Pa
- Sap Appendix Q (BRE) approved
- Low energy High performance DC fan
- SFP as low as 0.25 W.L.S.
- Optional C02 sensor
- Optional acoustic plus kit
- Only 4.3 kg in weight
- Slimline dimensions of 480x480x195mm
- 3 x Variable fan speeds
- 2+1 Year parts warranty*
- Optional 2 or 3 speed switch
- Suitable for wall or floor mounting
- Optional Humidity or CO2 box sensor
- Optional Wired / RF wall controller
- Optional App / BMS control
- Optional commissioning App kit
- Optional 7x 125 to 90 radial adaptors
- Optional fault indicator
- Optional laptop connection for commissioning
Demand Controlled Ventilation
Historically, MEV-units used to run continuously: 24 hours a day, 7 days a week. At a single set speed This was deemed to be “ok” so the energy losses were deemed to be small.
DUCO feels that this “old school”-way-of-thinking is a thing of the past and decided to go a step beyond the “normal” operation mode of a “traditional” MEV system.
DUCO offers true “on demand” solutions which result in true energetically optimised ventilation solutions:
To only ventilate, when necessary, where it is necessary and as long as it is necessary!
The DucoBox Silent has an internal humidity sensor that detects high humidity and increases the performance until the set level is reached again
It is also possible to install a CO2 box sensor inside the DucoBox Silent UK
With an “on demand” DUCO-system, the occupant can always be assured to breathe the best possible indoor air, whilst also using the least amount of energy! DUCO brings you the SMARTEST ventilation solutions!
External Control Components
The DucoBox Silent Connect can be linked with the following external control components.
Box Sensors
Box sensors can be installed very easily and quickly and provide CO2 and/or moisture measurement
in an air duct. They are wired directly to the circuit board. This means that no wiring for room
sensors need to be provided.
A DucoBox Silent contains a maximum of two box sensors – one CO2 Box sensor and/or one
Humidity Box Sensor – each of which can be clicked separately into a specific duct opening or
together into one duct opening of the DucoBox.
Smart Demand User controller
There are 3 types of User controllers are available in either wireless or wired versions and in black or white face plates
- Remote control (popular option)
- Remote Control with CO2 sensor
- Remote control with Humidity Sensor
The wired version will require the additional 24v Power supply
Duco Connectivity Board
The Duco Connectivity Board enables the Duco Installation App to be used on your phone or tablet
This PCB also enables interfacing for home automation and building management systems via REST API (locally or via the cloud) or Modbus TCP (locally). Both possible via Ethernet and Wi-Fi.
CO2 Room Sensors
The CO2 Room sensor is available in either wireless or wired versions and with black or white face plates
Switch Sensor
The Switch Sensor can perform either or both of the following functions:
Switch detection: the ventilation system will perform a function when closing a (two-pole) dry
contact. Suitable for toilet detection or overrule setting (only one function per switch sensor).
Repeater: the switch sensor is ideally suited as a repeater to strengthen the signal in the event of RF communication problems. In that case the switch sensor must be positioned in such a way that the distance to be bridged and/or interference by obstacles is reduced.
Silent Plus Kit
The Silent Plus Kit provides additional acoustic damping of up to 3 dB(A)!
The kit consists of three acoustic composite foam pads and three acoustic caps that are placed into the predesigned inserts inside the unit
Quiet-Vent adaptors
The Quiet-Vent 125 to 90 adapters allow you to connect the 90mm radial pipe directly to the unit avoiding the use of a distribution box that will provide many benefits over using solid rigid ducting
Up to 7 number 90mm radial ducts can be used on the unit
This option will reduce installation time over solid rigid duct, reduce cost as there is no need for a distribution box, and comply with the latest building control requirements
Fault Indicator
With the optional wall mounted fault indicator, you can be notified by colored indicator light when a fault is detected (max one per unit)
Boost switch
A boost switch will allow the user to manually increase or decrease the speed, there is a manual 2 speed and 3 speed switches available
Only one boost switch is recommended per unit and if the speed is set to high it will override any sensors and remain at that speed till manually reset to a lower speed
A boost switch is required to commission the unit