Domus HRX-E HERA Heat Recovery Unit
Product Part Number
Domus HRXE-HERA-H
Opposite Handed - HRXE-HERA-OPH
Description
The Domus HRXE-HERA-H provides a maximum flow rate of 288m3/hr suitable for a house up to 172 m2 floor area with up to 5 kitchens & bathrooms
Controllability is provided by an internal humidity sensors and optional room sensors or switches
(no digital controller is available for this model)
BPC Ventilation are the largest independent MVHR specialists and supply this unit with up to a 5-year parts warranty* and lifetime technical support on our top-quality systems,
Integral Humidity Sensor
The Domus unit has an Internal Humidity sensor that can provide a superior demand-controlled ventilation solution for your property
When the unit senses that the humidity exceeds the set point the unit will boost to that set by the commissioned boost speed. The humidity can be set on the front of the unit
We also advise an optional boost switch should be used local to the wet rooms
Filtration
2 x G3 filters are fitted to the unit that are easy and inexpensive to replace
(The filters are provided with plastic covers that should be removed before starting unit for first time)
CONTROL OPTIONS
The Domus units are controlled by one of the following:
- 4 x adjustable switches on the front of the unit
- Manual control Via optional 3 speed manual switch
- On-demand ventilation through built-in humidity sensors
- Additional external sensors achieving on-demand ventilation
- Switched live signal from light/remote switches
Heat Exchanger
This unit has a high-quality PVC counterflow heat exchanger with up to a 90% thermal efficiency protected with high-capacity filters on each side
The heat exchanger is easy to remove for maintenance and any accumulated condensation is easily dispersed via a drain at the bottom of the unit
Frost Protection
In the event of the intake air temperature at the unit dropping below the predetermined set point (-5°C as standard) the supply fan will reduce to minimum speed, once the temperature rises above the set point the fan will return to its commissioned speed.
Frost protection will only activate after ten days of continuous run time.
Summer By-Pass
The Domus units have a 100% summer by-Pass
If the indoor temperature Intake exceeds 25°C and the outdoor temperature is within comfort zones the summer by-pass is opened automatically to help provide a comfortable indoor temperature
Orientation
The Domus units can be right or left-handed and correct orientation should be checked before purchase
Construction
Manufactured of powder coated galvanised steel outer cover for durability and an inside EPP lining for quietness and efficiency
Mounting
The units are wall mounted as standard and are supplied with a wall bracket
AV (anti vibration mounting kit) - HRXE-HERA-AV
The optional anti vibration kit can be used for both wall and floor
Tank Stand
- The MVHR unit can be positioned on the optional tank stand using the Anti-vibration tray assembly discarding the angle brackets. (7)
Angled Brackets
- The unit can be installed above the floor on a wall angled bracket (8)
Accessories
- Condensation Drain – 297
- HEAR Replacement filters SPR428