{"product_id":"s-and-p-td-350-125-t-standard-in-line-fan-c-w-timer-rated-91-6l-s-2-speed-td-350-125-t","title":"S\u0026P TD-350\/125-T Standard In-Line Fan c\/w Timer - Rated @91.6l\/s 2 speed","description":"\u003ch3\u003eProduct Part Number\u003c\/h3\u003e\n\u003cp\u003eTD-350\/125-T\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eS\u0026amp;P TD-350\/125 T In-Line Mixed-Flow Fan\u003c\/strong\u003e is designed for use with 125mm circular ducting in residential and light commercial ventilation systems. Delivering an airflow of up to \u003cstrong\u003e330m³\/h (91.6l\/s)\u003c\/strong\u003e, its compact, low-profile construction makes it suitable for installation within ceiling voids and other areas where available space is limited.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAn integrated adjustable run-on timer allows the fan to continue operating for a selected period of between \u003cstrong\u003e1 and 30 minutes\u003c\/strong\u003e after the connected switch has been turned off. This helps remove remaining moisture, stale air and odours from bathrooms, utility rooms and other ventilated spaces.\u003c\/p\u003e\n\u003cp\u003eThe fan is manufactured with a durable polypropylene casing and ABS mixed-flow impeller. Its removable motor and impeller assembly allows servicing and maintenance to be carried out without disconnecting the adjoining ductwork. The motor includes ball bearings and thermal protection for reliable operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSoler \u0026amp; Palau (S\u0026amp;P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTD-350\/125 T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer reference\u003c\/td\u003e\n\u003ctd\u003e5211324800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan type\u003c\/td\u003e\n\u003ctd\u003eIn-line mixed-flow duct fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal duct diameter\u003c\/td\u003e\n\u003ctd\u003e125mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003eAdjustable run-on timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer range\u003c\/td\u003e\n\u003ctd\u003e1–30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of speeds\u003c\/td\u003e\n\u003ctd\u003eSingle speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum airflow\u003c\/td\u003e\n\u003ctd\u003e330m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum airflow\u003c\/td\u003e\n\u003ctd\u003e91.6l\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor speed\u003c\/td\u003e\n\u003ctd\u003e2,050rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum absorbed power\u003c\/td\u003e\n\u003ctd\u003e26W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum absorbed current\u003c\/td\u003e\n\u003ctd\u003e0.11A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound pressure level\u003c\/td\u003e\n\u003ctd\u003e33dB(A) at 3 metres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical supply\u003c\/td\u003e\n\u003ctd\u003e230V, single phase, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating air temperature\u003c\/td\u003e\n\u003ctd\u003e−20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical protection class\u003c\/td\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor insulation class\u003c\/td\u003e\n\u003ctd\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bearings\u003c\/td\u003e\n\u003ctd\u003eBall bearings, greased for life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor protection\u003c\/td\u003e\n\u003ctd\u003eSafety thermal protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCasing material\u003c\/td\u003e\n\u003ctd\u003ePolypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller material\u003c\/td\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed controller compatibility\u003c\/td\u003e\n\u003ctd\u003eNot suitable for speed control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall length\u003c\/td\u003e\n\u003ctd\u003e258mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum casing diameter\u003c\/td\u003e\n\u003ctd\u003e176mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection spigot diameter\u003c\/td\u003e\n\u003ctd\u003e123mm, suitable for 125mm ducting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eIntegrated removable support bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"S\u0026P","offers":[{"title":"Default Title","offer_id":56956487205190,"sku":"TD-350\/125-T","price":160.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0850\/5940\/4102\/files\/TD350-125FAN.png?v=1785758636","url":"https:\/\/bpcventilation.ie\/products\/s-and-p-td-350-125-t-standard-in-line-fan-c-w-timer-rated-91-6l-s-2-speed-td-350-125-t","provider":"BPC Ventilation Store","version":"1.0","type":"link"}